Input (DC)
Max. input voltage 1000 VDC
Operating voltage range 200 to 1000 VDC
MPP voltage range with max. Power 390 to 900 VDC
Nominal voltage 600 VDC
Max. current (per MPP tracker/total) 26 A/132 A
Max. number of MPP trackers 6 x 2 module strings
DC surge protection devices Type 2 (EN 61463-11), replaceable; combined Type 1+2 retrofittable

Output (AC)
Max. Apparent power 2) 55 kVA
Max. active power 2) 55 kW 3)
Nominal apparent power 2) 50 kVA
Voltage range AC 5) 230/400 V -20%/+30%, 3 phases + PE (△), 3 phases + N +
Max. Current 83 A
Frequency range 5) 50/60 Hz ± 5 Hz
Adjustment range of power factor 0.8 cap to 0.8 ind
AC surge protection devices Type 2 (EN 61463-11), replaceable; combined Type 1+2 retrofittable
Peak efficiency 98.7%
Efficiency EU 98.3%
Operating temperature range -25 to +60°C
Temperature range without power derating -25 to +50°C
Relative humidity 0 to 100%, non-condensing
Max. operating altitude 4000 m (above sea level)
Mounting options Wall mounting 6), ground mounting 7)
Topology Without transformer
Standard warranty 5 years (warranty extension available upon request
Connection type AC side Screw terminals
Connection type DC side 12 pairs of Amphenol H4 DC
Communication interfaces 2 x RS485, 2 x dry contacts, 1 x external power-off, 6 x digital inputs, Bluetooth®

This product is no longer available.

Zīmols: DELTA
Jauda (A): 50A